Automatic Can Seamer Seaming Machine Troubleshooting & Problems Solutions & Exception Handling
Automatic Can Seamer Seaming Machine Troubleshooting & Problems Solutions & Exception Handling.
- Fault Phenomenon: The block cans device cannot work after the start.
- Possible Causes: The detect sensor cannot detect the jar;
Method of Exclusion: Adjust the detect Sensor. - Possible Causes: The tank cylinder and solenoid valve do not work;
Method of Exclusion: Check the cylinder and solenoid valve
- Possible Causes: The detect sensor cannot detect the jar;
- Fault Phenomenon: Not beautiful of seamed.
- Possible Causes: The pressure wheel needs to be adjusted;
Method of Exclusion: Adjust the seaming wheel up and down left and right position.
- Possible Causes: The pressure wheel needs to be adjusted;
- Fault Phenomenon: One side is seaming good, and the other side cannot seam.
- Possible Causes: The turntable maybe offset;
Method of Exclusion: Adjust the turntable position.
- Possible Causes: The turntable maybe offset;
- Fault Phenomenon: Sometimes the load lids device is jam.
- Possible Causes: Load lids device failure;
Method of Exclusion: Check the load lids device.
- Possible Causes: Load lids device failure;
- Fault Phenomenon: Machine shutdown due to cannot detected the lids.
- Possible Causes: Detect lids sensor failure;
Method of Exclusion: Check the detect lids sensor.
- Possible Causes: Detect lids sensor failure;
- Fault Phenomenon: Seaming with no lids.
- Possible Causes: Detect lids sensor failure;
Method of Exclusion: Check the detect lids sensor.
- Possible Causes: Detect lids sensor failure;
- Fault Phenomenon: Lids offset when Load lids.
- Possible Causes: Load lids device offset;
Method of Exclusion: Adjust the load lids device.
- Possible Causes: Load lids device offset;